7-44
SL-1 XT system upgrade
553-3001-250 Standard 14.00 August 1996
76 Copy the contents of the data disks to the hard disk by entering
LD 43
RES
Insert the additional system disk (A2) when requested. When the restore
sequence is complete, enter
****
77 Remove disk A2 from drive A and insert disk A1.
78 Set the ENB/DIS switch on each MSI or EMSI card to DIS.
79 Remove each MSI or EMSI card. For MSI cards, set position 4 on switch
SW3 to ON. For EMSI cards, set position 4 on switch SW2 to ON.
80 Reinstall each MSI or EMSI card and set the ENB/DIS switch to ENB.
81 If you are installing an MDU and the system is not configured for a hard
disk drive, change the configuration record:
LD 17
IOTB
ADAN
****
82 Perform a data dump:
LD 43
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" displays on the terminal, enter
****
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
to load the program
to copy the entire contents of the backup to the
hard disk
to exit the program
to load the program
enter YES to change I/O devices
enter CHG HDK 0 to add a hard disk unit
to exit the program
to load the program
to begin the data dump
to exit the program