12-124
Upgrades to Meridian 1 option 81
Figure 12-27
NT6D60 Core module (rear)—connections for NTND13 and NTND11 cables
Core Module 0
18 17 16 15 14 13 12 11 10 9 8
Note : NT7D89 RS-232 cables and NT7D90 Ethernet cables are pre-installed at the factory.
553-3001-250 Standard 14.00 August 1996
Note: The following cables may already be connected in one of the
modules. If so, leave them connected and attach the loose end.
18 Connect the NTND13 IOP to IOP SCSI Cable from backplane connector
position 16A in Core 0 to backplane connector position 16A in Core 1.
19 Connect one NTND11 CP-to-CP Cable from backplane connector
position 14C in Core 0 to backplane connector position 14C in Core 1.
20 Connect another NTND11 cable from backplane connector position 14A
in Core 0 to backplane connector position 14A in Core 1.
A
B
C
D
E
F
NTND13 cable: 16A to 16A
NTND11 cables: 14C to 14C, 14A to 14A
21 For Group 0, attach adapters and cables from the NTND33CB kit to the
inside of the left I/O panel for each Core Module.
Note: For the left I/O panel, the inside of the I/O panel faces the
backplane, and the word LEFT faces the outside of the module. The slot
numbers listed below match the designations on the outside of the panel.
Core Module 1
18 17 16 15 14 13 12 11 10 9 8
A
B
C
D
E
F
553-5553