12-178
Upgrades to Meridian 1 option 81
553-3001-250 Standard 14.00 August 1996
Note: If the number of network groups configured in the system does
not match the number of network groups equipped, you must add or
remove groups. See the X11 input/output guide (553-3001-400) for
procedures describing adding and removing groups.
8
Re-map all I/O ports (except CPSI ports) to the proper groups (see
Table 12-40). The group number of these ports is determined by the
physical location of the card. The configuration information must match
the CNI configuration.
Table 12-40
LD 17: Configuring I/O ports
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
CHG terminal
x
GRP
g
Note: The History File requires a dedicated I/O port.
9
Evaluate the number of call registers and 500 telephone buffers that are
configured for the system (suggested minimum values are 5000 and
1000, respectively). Refer to Meridian 1 capacity engineering
(553-3001-149). If changes are required, reconfigure the values in
LD 17.
10 Load overlay 22 and print the Configuration Record to verify the above
changes:
LD 22
REQ PRT
TYPE CFN
****
Comments
x = terminal number (0-15)
g = network group (0-4)
to load the program
to set the print option
to print the configuration
to exit the program