Nortel Meridian 1 Manual page 891

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

Table 12-26
Group 2, 3, and 4 connections on the right I/O panel: NTND94DA cables
Core 0
cable labels
CPU0-CNI-9F to
3PE-GRP2/0-J4
CPU0-CNI-9D to
3PE-GRP2/0-J3
CPU0-CNI-10C to
3PE-GRP3/0-J4
CPU0-CNI-10A to
3PE-GRP3/0-J3
CPU0-CNI-10F to
3PE-GRP4/0-J4
CPU0-CNI-10D to
3PE-GRP4/0-J3
34 For Group 2, Group 3, and Group 4 (if equipped), attach adapters and
cables from the NTND33CC kits to the inside of the right I/O panel for
each Core Module.
Note: On the right I/O panel, the inside of the panel faces the backplane,
and the word RIGHT faces the outside of the module. The slot numbers
listed below match the designations on the outside of the panel.
35 Permanently remove the cable restraint bracket on the inside of the I/O
panel. Remove the pan-head screw and lift the bracket away from the
lower edge of the J10 opening.
36 Attach a filter adapter (P0369107) at slot J11.
37 For all groups, connect the NTND94DA cables to the I/O panel as listed
in Table 12-26.
38 Feed the cables from the I/O panel through the panel opening and secure
the panel with the eight mounting screws.
39 Connect the cables to the backplane connector positions indicated on the
cable label and listed in Table 12-26.
Core 1
cable labels
CPU1-CNI-9F to
3PE-GRP2/1-J4
CPU1-CNI-9D to
3PE-GRP2/1-J3
CPU1-CNI-10C to
3PE-GRP3/1-J4
CPU1-CNI-10A to
3PE-GRP3/1-J3
CPU1-CNI-10F to
3PE-GRP4/1-J4
CPU1-CNI-10D to
3PE-GRP4/1-J3
Upgrade system installation Upgrading to Meridian 1 system options
Upgrades to Meridian 1 option 81
I/O slot
J1 (group 2)
J2 (group 2)
J5 (group 3)
J6 (group 3)
J9 (group 4)
J10 (group 4)
12-127
Backplane
connector
9F (group 2)
9D (group 2)
10C (group 3)
10A (group 3)
10F (group 4)
10D (group 4)