p0400[0...n]

Encoder type selection / Enc_typ sel

DC_CTRL,
Can be changed: C2(1, 4)
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
3001: 1024 HTL A/B R
3002: 1024 TTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3006: 1024 TTL A/B
3007: 2048 HTL A/B
3008: 2048 TTL A/B
3009: 1024 HTL A/B unipolar
3011: 2048 HTL A/B unipolar
3020: 2048 TTL A/B R, with sense
3081: SSI, Singleturn, 24 V
3082: SSI, Multiturn 4096, 24 V
3090: 4096, HTL, A/B, SSI, Singleturn
9999: User-defined
20000: Encoder from OEM encoder list
Notice:
An encoder type with p0400 < 9999 defines an encoder for which there is an encoder parameter list.
When selecting a catalog encoder (p0400 < 9999) the parameters from the encoder parameter list cannot be
changed (write protection). To remove write protection, the encoder type should be set to a third-party encoder
(p0400 = 9999).
Note:
The connected encoder can be identified by p0400 = 10000. This assumes that the encoder supports this method,
which is possible in the following cases: Motor with DRIVE-CLiQ, encoder with EnDat interface, DRIVE-CLiQ
encoder.
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
When using an encoder with track A/B and zero pulse, as standard, fine synchronization is not set using a zero mark.
If, for a synchronous motor, fine synchronization is to be realized using a zero mark, then the following must be
executed:
- set p0400 to 9999
- set p0404.15 to 1
Prerequisite:
Coarse synchronization must be selected (e.g. pole position identification) and the zero pulse of the encoder must be
either mechanically or electronically (p0431) adjusted to the pole position.
For p0400 = 10000 the following applies:
If an identification is not possible, then p0400 is set to 0.
p0401[0...n]

Encoder type OEM selection / Enc type OEM sel

DC_CTRL,
Can be changed: C2(1, 4)
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Selects the encoder from the list of encoder types that the OEM supports.
Note:
The connected encoder can be identified by p0400 = 10000. This means that the encoder must support this and is
possible in the following cases: Motor with DRIVE-CLiQ, encoder with EnDat interface.
If an identification is not possible, then p0400 is set to 0.
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
Using p0400 = 20000, the encoder type can be selected from the list of OEM encoders using p0401.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No encoder
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
20000
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
32767
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 1580, 4704
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
63