Ci: Speed Limiting Controller Signal Source For Pos Torque Limit; Ci: Speed Limiting Controller Signal Source For Neg Torque Limit; Speed Limiting Controller Max Speed Pos Direction Of Rotation; Speed Limiting Controller Max Speed Neg Direction Of Rotation - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50510
CI: Speed limiting controller signal source for pos torque limit / T lim pos sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the positive torque limit on the speed limiting controller.
Dependency:
Refer to: r52136
Note:
This parameter specifies which parameter is to be injected as the limit value for torque limiting 1 (r52136).
p50511
CI: Speed limiting controller signal source for neg torque limit / T lim neg sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the negative torque limit on the speed limiting controller.
Dependency:
Refer to: r52137
Note:
This parameter specifies which parameter is to be injected as the limit value for torque limiting 2 (r52137).
p50512[0...n]
Speed limiting controller max speed pos direction of rotation / n_max pos dir rot
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Sets the maximum speed for the positive direction of rotation on the speed limiting controller.
p50513[0...n]
Speed limiting controller max speed neg direction of rotation / n_max neg dir
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.0 [%]
Description:
Sets the maximum speed for the negative direction of rotation on the speed limiting controller.
p50515[0...n]
Speed limiting controller P gain / n_lim Kp
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.10
Description:
Sets the P gain on the speed limiting controller.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
0.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
200.00
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
52002[0]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
52004[0]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
105.0 [%]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
-105.0 [%]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
3.00
469

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents