Parallel Interface Can Diagnostic Information / Pi Can Diag Info; Parallel Interface Transmit Data Display / Pi Trans Data Disp - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r51811

Parallel interface CAN diagnostic information / PI CAN diag info

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the CAN diagnostic information for the parallel interface.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
r51813[0...15]

Parallel interface transmit data display / PI trans data disp

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the data selected for transmission.
Index:
[0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
[5] = Word 6
[6] = Word 7
[7] = Word 8
[8] = Word 9
[9] = Word 10
[10] = Word 11
[11] = Word 12
[12] = Word 13
[13] = Word 14
[14] = Word 15
[15] = Word 16
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Abort acknowledge flag
Write denied flag
Wake-up flag
Received msg lost flag
Bus-off condition flag
Error passive mode flag
Warning level flag
Form error flag
Bit error flag
Stuck at dominant bit
CRC error
Stuff bit error
ACK error
Bus-off status
Error passive state
Warning status
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 9350
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Access level: 1
Func. diagram: 9355
Unit selection: -
Expert list: 1
Factory setting
-
FP
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
9350
549