Emf Setpoint Reduction Line Voltage Smoothing Time; Emf Setpoint Reduction Line Voltage Upper Limit; Emf Setpoint Reduction Line Voltage Lower Limit; Emf Setpoint Reduction Evaluation Factor / Emf Set Eval_Fact - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50285[0...n]
EMF setpoint reduction line voltage smoothing time / EMF set line t_sm
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the smoothing time for the line voltage for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50287, p50288, p50289, r52294
p50286[0...n]
EMF setpoint reduction line voltage upper limit / EMF set line upper
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
100.0 [%]
Description:
Sets the upper limit for the line voltage for EMF setpoint reduction.
Dependency:
Refer to: p50287, p50288, p50289, r52294
p50287[0...n]
EMF setpoint reduction line voltage lower limit / EMF set line lower
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Sets the lower limit for the line voltage for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50288, p50289, r52294
p50288[0...n]

EMF setpoint reduction evaluation factor / EMF set eval_fact

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Sets the evaluation factor for the EMF setpoint reduction.
Dependency:
Refer to: p50286, p50287, p50289, r52294
p50289[0...n]
BI: EMF setpoint reduction activation signal source / EMF set act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to activate the EMF setpoint reduction.
Dependency:
Refer to: p50285, p50286, p50287, p50288, r52294
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
150.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.0 [%]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6895
Unit selection: -
Expert list: 1
Factory setting
0.00 [s]
Access level: 2
Func. diagram: 6895
Unit selection: -
Expert list: 1
Factory setting
110.0 [%]
Access level: 2
Func. diagram: 6895
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 6895
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 2
Func. diagram: 6895
Unit selection: -
Expert list: 1
Factory setting
0