r53010.0...15

CO/BO: CUD digital inputs, status / CUD DI status

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the CUD's digital inputs.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
For bits 08 to 15:
The terminal must be set as an input (p50789[0...3] = 0).
Note:
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
r53020.0...7

CO/BO: CUD digital outputs status / CUD DO status

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the CUD's digital outputs.
Bit field:
Bit
00
01
02
03
04
05
06
07
Dependency:
For bits 04 to 07:
The terminal must be set as an output (p50789[0...3] = 1).
Note:
DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
DI 0 (X177.11)
DI 0 inverted (X177.11)
DI 1 (X177.12)
DI 1 inverted (X177.12)
DI 2 (X177.13)
DI 2 inverted (X177.13)
DI 3 (X177.14)
DI 3 inverted (X177.14)
DI/DO 4 (X177.15)
DI/DO 4 inverted (X177.15)
DI/DO 5 (X177.16)
DI/DO 5 inverted (X177.16)
DI/DO 6 (X177.17)
DI/DO 6 inverted (X177.17)
DI/DO 7 (X177.18)
DI/DO 7 inverted (X177.18)
Signal name
DO 0 (X177.19)
DO 1 (X177.20)
DO 2 (X177.21)
DO 3 (X177.22)
DI/DO 4 (X177.15)
DI/DO 5 (X177.16)
DI/DO 6 (X177.17)
DI/DO 7 (X177.18)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2050, 2060,
2065, 2580
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Access level: 2
Func. diagram: 2055, 2060,
2065
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
FP
2050
2050
2050
2050
2050
2050
2050
2050
2060
2060
2060
2060
2065
2065
2065
2065
FP
2055
2055
2055
2055
2060
2060
2065
2065