p50785

CUD digital input/output 4 delay time / CUD DI/DO 4 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital input/output 4 (X177.15) on the CUD.
Dependency:
The terminal must be set as an output (p50789[0] = 1).
Refer to: p50789
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50786

CUD digital input/output 5 delay time / CUD DI/DO 5 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital input/output 5 (X177.16) on the CUD.
Dependency:
The terminal must be set as an output (p50789[1] = 1).
Refer to: p50789
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50787

CUD digital input/output 6 delay time / CUD DI/DO 6 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital input/output 6 (X177.17) on the CUD.
Dependency:
The terminal must be set as an output (p50789[2] = 1).
Refer to: p50789
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50788

CUD digital input/output 7 delay time / CUD DI/DO 7 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital input/output 7 (X177.18) on the CUD.
Dependency:
The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2060
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2060
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2065
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2065
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
517