Bo: Tm31 Temperature Evaluation Status / Tm31 Temp Status; Co: Tm150 Temperature Actual Value / Tm150 Temp_Act Val - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Dependency:
Refer to: p4102, p4103, r4105, p4118
r4104.0...1

BO: TM31 temperature evaluation status / TM31 temp status

TM31
Can be changed: -
Data type: Unsigned16
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Display and binector output for the status for the Terminal Module 31 (TM31).
Bit field:
Bit
00
01
Dependency:
Refer to: p4102
r4105[0...11]

CO: TM150 temperature actual value / TM150 temp_act val

TM150
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [°C]
Description:
Displays the temperature actual value for the Terminal Module 150 (TM150)
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
[5] = Temperature channel 5
[6] = Temperature channel 6
[7] = Temperature channel 7
[8] = Temperature channel 8
[9] = Temperature channel 9
[10] = Temperature channel 10
[11] = Temperature channel 11
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Channel 0 alarm present
Channel 0 fault present
Channel 1 alarm present
Channel 1 fault present
Channel 2 alarm present
Channel 2 fault present
Channel 3 alarm present
Channel 3 fault present
Channel 4 alarm present
Channel 4 fault present
Channel 5 alarm present
Channel 5 fault present
Channel 6 alarm present
Channel 6 fault present
Channel 7 alarm present
Channel 7 fault present
Channel 8 alarm present
Channel 8 fault present
Channel 9 alarm present
Channel 9 fault present
Channel 10 alarm present
Channel 10 fault present
Channel 11 alarm present
Channel 11 fault present
Signal name
Alarm is present
Fault is present
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2006
Max
- [°C]
2 Parameters
2.2 List of parameters
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 1
Func. diagram: 9549, 9576
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 1
Func. diagram: 9626, 9627
Unit selection: -
Expert list: 1
Factory setting
- [°C]
FP
9626
9626
9626
9626
9626
9626
9626
9626
9626
9626
9626
9626
9627
9627
9627
9627
9627
9627
9627
9627
9627
9627
9627
9627
FP
-
-