Co/Bo: Binector-Connector Converter Output / Bin/Con Outp; Co: Parallel Interface Master Receive Data Word By Word - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52620.0...15

CO/BO: Binector-connector converter output / Bin/con outp

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output on the binector-connector converter.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
Refer to: p51117
Note:
The individual signals supplied via binector input p51117[0 to 15] are combined to form connector output r52620.
r52700[0...15]
CO: Parallel interface master receive data word by word / Master recv wbw
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the word-by-word receive data from the master on the parallel interface.
Index:
[0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
[5] = Word 6
[6] = Word 7
[7] = Word 8
[8] = Word 9
[9] = Word 10
[10] = Word 11
[11] = Word 12
[12] = Word 13
[13] = Word 14
[14] = Word 15
[15] = Word 16
Dependency:
Refer to: r52720
Note:
The receive data in word 1 is also available in non-scaled format bit by bit and word by word for further
interconnection.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
P2P binector-connector converter bit 0
P2P binector-connector converter bit 1
P2P binector-connector converter bit 2
P2P binector-connector converter bit 3
P2P binector-connector converter bit 4
P2P binector-connector converter bit 5
P2P binector-connector converter bit 6
P2P binector-connector converter bit 7
P2P binector-connector converter bit 8
P2P binector-connector converter bit 9
P2P binector-connector converter bit 10
P2P binector-connector converter bit 11
P2P binector-connector converter bit 12
P2P binector-connector converter bit 13
P2P binector-connector converter bit 14
P2P binector-connector converter bit 15
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 9300
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Access level: 2
Func. diagram: 9352
Unit selection: -
Expert list: 1
Factory setting
- [%]
FP
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
9300
605