2 Parameters
2.2 List of parameters
p50465[0...n]

Motorized potentiometer expansion factor / MotP exp fact

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the expansion factor on the motorized potentiometer.
Value:
0:
1:
Dependency:
Refer to: p50462, p50463, p50464
Note:
The expansion factor affects the following parameters:
- p50462 (ramp-up time)
- p50463 (ramp-down time)
- p50464 (time difference for dy/dt)
p50466[0...n]
CI: Motor potentiometer setting value signal source / MotP s val sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setting value for the motorized potentiometer.
Dependency:
Refer to: p50472
Note:
The setting value (CI: p50466) becomes effective on a 0/1 edge of the setting command (BI: p50472).
p50467[0...n]

Motorized potentiometer starting value / MotP start value

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the starting value on the motorized potentiometer.
Dependency:
Refer to: p50473
Note:
The value is only effective when saving of the output value is de-activated (p50473 = 0).
p50468[0...n]

Motorized potentiometer maximum speed / MotP n_max

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the maximum speed on the motorized potentiometer.
Dependency:
Refer to: p50471
Note:
This parameter is only effective in manual mode (p50471 = 0).
The setpoint output from the motorized potentiometer is limited to this value.
462
Factor 1
Factor 60
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]