Co: Armature Current Actual Value Averaged Over 1 Cycle; Co: Cl-Loop Arm Curr Control Curr Controller Actual Value Abs Value; Co: Armature Current Actual Value Internal Absolute Value; Co: Armature Current Actual Value Internal Signed - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52114
CO: Armature current actual value averaged over 1 cycle / Ia act 1 cyc
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the signed armature current actual value.
The value is averaged over 1 firing cycle.
r52115
CO: Cl-loop arm curr control curr controller actual value abs value / Ia ctr I_act abs
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the absolute value of the current controller actual value for closed-loop armature
current control.
r52116
CO: Armature current actual value internal absolute value / A I_act int abs
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the absolute value of the internal armature current actual value.
The value is averaged over one firing cycle.
r52117
CO: Armature current actual value internal signed / A I_act int sign
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signed internal armature current actual value.
The value is averaged between the centers of the firing intervals.
r52118
CO: Cl-loop arm curr control curr controller setpoint absolute value / Ia ctr I_set abs
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the absolute value of the current controller setpoint for closed-loop armature current
control.
Dependency:
Refer to: r50020
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6851
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6851
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6851
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]