2 Parameters
2.2 List of parameters
Note:
The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
p50304[0...n]

RFG ramp-down time 1 / RFG t_ramp-dn 1

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the ramp-down time for ramp-function generator parameter set 1.
Note:
The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
p50305[0...n]

RFG initial rounding 1 / RFG init rndg 1

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the initial rounding for ramp-function generator parameter set 1.
Dependency:
Refer to: p50295
Note:
The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
p50306[0...n]

RFG final rounding 1 / RFG fin rndg 1

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the final rounding for ramp-function generator parameter set 1.
Dependency:
Refer to: p50295
Note:
The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
438
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
100.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
100.00 [s]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 1
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0.00 [s]
Access level: 1
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0.00 [s]