Ci: Messages For Speed Less Than Min Speed Signal Source For Act Val; Ci: Messages Polarity Speed Setpoint Signal Source; Ci: Signal Source For Overspeed Messages; Ci: Messages For Set/Act Val Dev 2 Signal Source For Speed Setpoint - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50593

CI: Messages for speed less than min speed signal source for act val /

Msg n<n_min sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the "Speed less then minimum speed" message.
Dependency:
Refer to: r53025
p50594[0...n]
CI: Messages polarity speed setpoint signal source / MsgPol n_set S_src
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the "Speed setpoint polarity" message.
Dependency:
Refer to: p50372, r53025
p50595
CI: Signal source for overspeed messages / Msg n_over sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value for the overspeed message.
Dependency:
Refer to: p50380, p50381, r53025
Refer to: F60038
p50596

CI: Messages for set/act val dev 2 signal source for speed setpoint /

Msg dev2 set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed setpoint for the "Setpoint/actual value deviation 2" message.
Dependency:
Refer to: p50597, r53025
p50597
CI: Messages for set/act val dev 2 signal source for speed act val / Msg dev2 act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value for the "Setpoint/actual value deviation 2" message.
482
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
52167[0]
Access level: 2
Func. diagram: 8025
Unit selection: -
Expert list: 1
Factory setting
52170[0]
Access level: 2
Func. diagram: 8025
Unit selection: -
Expert list: 1
Factory setting
52167[0]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
52174[0]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
52167[0]