2 Parameters
2.2 List of parameters
p50320[0...n]
Setpoint processing main setpoint factor / m_set_factor
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets the fixed factor for the main setpoint.
Dependency:
Refer to: p50322
p50321[0...n]
Setpoint processing additional setpoint factor / Add_set_factor
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets the fixed factor for the additional setpoint.
Dependency:
Refer to: p50323
p50322[0...n]
CI: Setpoint processing signal source for main setpoint factor / M set factor sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the variable factor for the main setpoint.
Dependency:
Refer to: p50320
p50323[0...n]
CI: Setpoint processing signal source for additional setpoint factor / Add set fac sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the variable factor for the additional setpoint.
Dependency:
Refer to: p50321
p50330[0...n]
RFG time unit / RFG time unit
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the unit for the ramp-function generator times.
Value:
0:
1:
442
Second
Minute
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 3
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 3150, 3152
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM