Co: N-Dependent Current Limitation Armature Current Setpoint Limit; Co: I2T Monitoring Armature Current Setpoint After Limitation; Co: Current Limitation Minimum Positive Armature Current Limit; Co: Current Limitation Maximum Negative Armature Current Limit - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
This parameter is calculated when Ua_set is fed into the gating unit.
-100 % corresponds to 180 degrees
+100% corresponds to 0 degrees
r52129
CO: n-dependent current limitation armature current setpoint limit / I_lim Ia set lim
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature current setpoint after speed-dependent current limitation.
Dependency:
Refer to: p50109
r52130
CO: I2t monitoring armature current setpoint after limitation / I2t Ia set n lim
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature current setpoint after limitation by means of I2t monitoring as a
percentage of r50072[1].
r52131
CO: Current limitation minimum positive armature current limit / Ia lim pos min
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the minimum positive armature current limit.
r52132
CO: Current limitation maximum negative armature current limit / Ia lim neg max
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the maximum negative armature current limit.
r52133
CO: Current limitation setpoint before limitation (with add_s) / Set bef lim w add
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature current controller setpoint before limitation (with additional setpoint).
572
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 8042
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6840, 6845
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6840, 6845
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6840, 8042
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading