Auto-Reversing Stage Simulation Mode / Auto-Rev Simul; Line Zero Crossings Offset Angle Fixed / Line Offset Fixed; Line Zero Crossings Offset Angle Thyristor Pair-Dependent Factor - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
Refer to: p50082
p51840

Auto-reversing stage simulation mode / Auto-rev simul

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to control simulation mode in the auto-reversing stage.
Value:
0:
11:
12:
13:
14:
15:
16:
21:
22:
23:
24:
25:
26:
Note:
The simulation mode can only be activated in operating states >= o7.0.
p51845

Line zero crossings offset angle fixed / Line offset fixed

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-120.00 [°]
Description:
Sets a fixed offset angle between the line zero crossings at the power unit and the synchronizing voltage.
Dependency:
Refer to: p51846, p51847
p51846[0...5]
Line zero crossings offset angle thyristor pair-dependent factor / Line offset Fact
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-10.00 [°]
Description:
Sets an offset angle dependent on a thyristor pair between the line zero crossings at the power unit and the
synchronizing voltage.
Index:
[0] = Thyristor pair 1-6 (UV+)
[1] = Thyristor pair 1-2 (WU-)
[2] = Thyristor pair 2-3 (VW+)
[3] = Thyristor pair 3-4 (UV-)
[4] = Thyristor pair 4-5 (WU+)
[5] = Thyristor pair 5-6 (VW-)
Dependency:
Refer to: p51845, p51847
556
No simulation mode
Fire thyristor 11
Fire thyristor 12
Fire thyristor 13
Fire thyristor 14
Fire thyristor 15
Fire thyristor 16
Fire thyristor 21
Fire thyristor 22
Fire thyristor 23
Fire thyristor 24
Fire thyristor 25
Fire thyristor 26
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
26
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
120.00 [°]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10.00 [°]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6865
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
0.00 [°]
Access level: 3
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
0.00 [°]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents