2 Parameters
2.2 List of parameters
510:
511:
701:
r50060[0...14]

Software version / SW version

DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the existing software versions.
Index:
[0] = Complete device version external
[1] = Complete device version internal
[2] = DSAC Bootloader Version
[3] = BIOS version
[4] = Configuration EEPROM version
[5] = Base system version
[6] = DC MASTER version
[7] = TMS version
[8] = TMS image version
[9] = TMS bootloader version
[10] = TMS bootloader image version
[11] = Powerstack properties version
[12] = In-plant information
[13] = DCC version
[14] = FBLOCKS version
Note:
Some of these software versions are also displayed at other parameters.
Index 0 <--> r7844[1]
Index 1 <--> r7844[0]
Index 2 <--> r0197
Index 5 <--> r0018
Index 6, 13, 14 <--> r4957[x]
r50063[0...1]

CUD information / CUD info

DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays information about the Control Unit DC MASTER (CUD).
Index:
[0] = CUD position
[1] = CUD variant
Note:
Re index 0:
Indicates the position of the Control Unit DC MASTER (CUD) in the device.
- Value = 0: CUD is installed on the left.
- Value = 1: CUD is installed on the right.
Re index 1:
Indicates the variant of the Control Unit DC MASTER (CUD).
- Value = 0: CUD is the standard version.
- Value = 1: CUD is the advanced version.
386
Recording the friction characteristic - 90% rated speed
Recording the friction characteristic - 100% rated speed
Calculation is carried out
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM