p0005[0...1]

BOP operating display selection / BOP op_disp sel

TM150, TM15DI_DO,
Can be changed: U, T
TM31
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter number and parameter index for display for p0006 = 2, 4 for the Basic Operator Panel (BOP).
Examples for the SERVO drive object:
p0005[0] = 21, p0005[1] = 0: Actual speed smoothed (r0021)
p0005[0] = 25, p0005[1] = 0: Output voltage smoothed (r0025)
Index:
[0] = Parameter number
[1] = Parameter index
Dependency:
Refer to: p0006
Note:
Procedure:
1.
The parameter number to be displayed should be set in index 0. Only the monitoring parameters (read-only
parameters) can be set that actually exist for the actual drive object.
If the set parameter number is not indexed, or if there is an index in index 1 that lies outside the valid range of the set
parameter, then index 1 is automatically set to 0.
2.
The index that belongs to the parameter set in index 0 should be set in index 1. The permissible changes in index 1
always depend on the parameter number set in index 0.
p0006

BOP operating display mode / BOP op_ disp mode

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S, DC_CTRL,
P-Group: -
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
4
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready for
operation" and "operation".
Value:
4:
Dependency:
Refer to: p0005
Note:
Mode 4 is available for all drive objects.
p0006
BOP operating display mode / BOP op_ disp mode
TM150, TM15DI_DO,
Can be changed: U, T
TM31
Data type: Integer16
P-Group: -
Not for motor type: -
Min
4
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready for
operation" and "operation".
Value:
4:
Dependency:
Refer to: p0005
Note:
Mode 0 ... 3 can only be selected if also r0020, r0021 are available on the drive object.
Mode 4 is available for all drive objects.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
p0005
p0005
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 2
[1] 0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4