Line Analysis Field Line Phase Offset / Field Line Ph Offs; Co: Line Analysis Armature Line Zero Crossing Positive Phase Uv; Co: Line Analysis Armature Line Zero Crossing Negative Phase Uv; Co: Line Analysis Armature Line Zero Crossing Positive Phase Vw - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52966

Line analysis field line phase offset / Field line ph offs

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [V]
Description:
Displays the DC offset (= direct-current component) of the field line phases in volts.
r52970
CO: Line analysis armature line zero crossing positive phase UV / Arm zero pos UV
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last positive zero crossing of armature phase UV.
Note:
The value is displayed in [10 ns] unit.
r52971
CO: Line analysis armature line zero crossing negative phase UV / Arm zero neg UV
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last negative zero crossing of armature phase UV.
Note:
The value is displayed in [10 ns] unit.
r52972
CO: Line analysis armature line zero crossing positive phase VW / Arm zero pos VW
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last positive zero crossing of armature phase VW.
Note:
The value is displayed in [10 ns] unit.
r52973
CO: Line analysis armature line zero crossing negative phase VW / Arm zero neg VW
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last negative zero crossing of armature phase UV.
Note:
The value is displayed in [10 ns] unit.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 6952
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
627