Cud Digital Outputs Inversion / Cud Do Inv; Bi: Cud Digital Output 0 Signal Source / Cud Do 0 Sig S; Bi: Cud Digital Output 1 Signal Source / Cud Do 1 Sig S; Bi: Cud Digital Output 2 Signal Source / Cud Do 2 Sig S - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50770[0...3]

CUD digital outputs inversion / CUD DO inv

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to invert the signals at the CUD's digital outputs.
Value:
0:
1:
Index:
[0] = DO 0 (X177.19)
[1] = DO 1 (X177.20)
[2] = DO 2 (X177.21)
[3] = DO 3 (X177.22)
Note:
DO: Digital Output
p50771

BI: CUD digital output 0 signal source / CUD DO 0 sig s

DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for digital output 0 (X177.19) on the CUD.
p50772

BI: CUD digital output 1 signal source / CUD DO 1 sig s

DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for digital output 1 (X177.20) on the CUD.
p50773

BI: CUD digital output 2 signal source / CUD DO 2 sig s

DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for digital output 2 (X177.21) on the CUD.
p50774
BI: CUD digital output 3 signal source / CUD DO 3 sig s
DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for digital output 3 (X177.22) on the CUD.
Note:
A restart is required if p50774 is logically combined with (2)r51579.0!
514
Not inverted
Inverted
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents