Co: Measurement Results Asic 2 Raw Values - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
For devices with 575 V:
- 0 corresponds to -1036.2 V
- 32767 corresponds to 0 V
- 65535 corresponds to +1036.2 V
For devices with 1000 V:
- 0 corresponds to -1795.2 V
- 32767 corresponds to 0 V
- 65535 corresponds to +1795.2 V
Index:
[0] = Phase VU
[1] = Phase VW
[2] = Voltage CV
[3] = Voltage CD
[4] = Voltage S13V
Dependency:
Refer to: r52922, r52923
Note:
This parameter is used solely for internal diagnostics.
r52922[0...2]
CO: Measurement results ASIC 2 raw values / Meas res ASIC2 raw
DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the raw values from the measurements of Power Stack ASIC 2.
For voltage channels:
- 0 corresponds to -825.0 V
- 32767 corresponds to 0 V
- 65535 corresponds to +825.0 V
For the current channel:
- 49151 corresponds to 0 A
For devices with rated field current = 3A:
- 8218 corresponds to 3 A
For devices with rated field current = 5 A:
- 9065 corresponds to 5 A
For devices with rated field current = 10 A:
- 9065 corresponds to 10 A
For devices with rated field current = 15 A:
- 29108 corresponds to 15 A
For devices with rated field current = 25 A:
- 15746 corresponds to 25 A
For devices with rated field current = 30 A & A7115:
- 9065 corresponds to 30 A
For devices with rated field current = 30 A & A7116:
- 24608 corresponds to 30 A
For devices with rated field current = 40 A:
- 16427 corresponds to 40 A
For devices with rated field current = 85 A:
- 14382 corresponds to 85 A
Index:
[0] = Raw value voltage 3U3W
[1] = Raw value voltage 3C3D
[2] = Raw value field current
Dependency:
Refer to: r52921, r52923
Note:
This parameter is used solely for internal diagnostics.
624
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading