Co: Cl-Loop Field Curr Ctrl Current Controller Actual Value; Co: Field Current Actual Value Internal Absolute Value; Co: Closed-Loop Field Current Control Current Controller Setpoint; Co: Closed-Loop Field Current Control Pre-Control Output - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r52265
CO: Cl-loop field curr ctrl current controller actual value / If_ctr act
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the field current controller's actual value.
r52266
CO: Field current actual value internal absolute value / If_act int abs
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the absolute value of the internal field current actual value as a percentage of p50073.01.
r52268
CO: Closed-loop field current control current controller setpoint / If_ctr set
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the field current controller's setpoint.
r52271
CO: Closed-loop field current control pre-control output / If_ctr prec outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of pre-control for closed-loop field current control.
r52273
CO: Field current setpoint limiting upper limit output / If lim up lim
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the upper limit of the field current setpoint.
Dependency:
Refer to: r50073, p50102, p50613
588
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 6905, 6910,
8025, 8044
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6912
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6910, 8025,
8044
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6905
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents