Armature Current Zero Current Signal / Ia I=0 Signal; Thyristor Code / Thyr_Code - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
41, 42:
MI, MII Alpha-W pulse with second pulse in the old torque direction.
Cause: additional Alpha-W pulses according to p50179.
51, 52:
MI, MII Alpha-W pulse without second pulse in the old torque direction.
Cause: additional Alpha-W pulses according to p50161.
60, 61, 62:
M0, MI, MII torque direction according to p51840 (simulation operation).
71: MI the command "simultaneously fire all thyristors" (according to p50176) was performed.
81: MI the torque direction specified by the thyristor check was realized.
82: MII the torque direction specified by the thyristor check was realized.
95, 96, 97:
M0, MI, MII the torque direction of the parallel switching master was realized.
Note:
This parameter is only for internal SIEMENS troubleshooting.
r52982

Armature current zero current signal / Ia I=0 signal

DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the number of zero current signals of the armature current.
For scan values below the threshold I = 0, the counter is incremented.
The counter is reset in the following cases:
- firing pulse.
- scan value above the threshold for I = 0.
Note:
This parameter is only for internal SIEMENS troubleshooting.
The scan values are every 62.5 µs.
The threshold for I = 0 is 1 % of the rated unit current.
r52983

Thyristor code / Thyr_code

DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the thyristor code.
Bit 0 = 1: Thyristor 1 was fired
...
Bit 5 = 1: Thyristor 6 was fired
Bit 6 = 1: thyristors were fired for torque direction 1
Bit 7 = 1: thyristors were fired for torque direction 2
Note:
This parameter is only for internal SIEMENS troubleshooting.
630
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM