Ci: Signal Source For Speed Controller Actual Value; Ci: Signal Source For Field Gating Unit Input Value; Ci: Field Curr Setp Limiting Setpoint Sig Source / If_Lim Set Sig S; Ci: Cl-Loop Field Current Ctrl Sig Source For Field Current Act Val - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50609[0...n]
CI: Signal source for speed controller actual value / n_ctr act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the actual value on the speed controller.
Dependency:
Refer to: p50083
p50610
CI: Signal source for field gating unit input value / Field g unit sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the input value on the field gating unit.
p50611[0...3]

CI: Field curr setp limiting setpoint sig source / If_lim set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for generating the field current setpoint (CO: r52275).
Dependency:
Refer to: r52275
p50612[0...1]
CI: Cl-loop field current ctrl sig source for field current act val / If_ctr If_ac sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the field current actual value for closed-loop field current control.
p50613[0...4]
CI: Field current setpoint limiting sig source for var upper limit / If_li up li sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for generating the upper limit of the field current setpoint (CO: r52273).
Dependency:
Refer to: r50073, p50102, r52273
486
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 6915
Unit selection: -
Expert list: 1
Factory setting
52252[0]
Access level: 3
Func. diagram: 6905
Unit selection: -
Expert list: 1
Factory setting
[0] 52277[0]
[1] 0
[2] 0
[3] 0
Access level: 3
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
[0] 52266[0]
[1] 0
Access level: 3
Func. diagram: 6905
Unit selection: -
Expert list: 1
Factory setting
1
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents