p50300[0...n]
RFG positive setpoint limit after ramp-function generator / RFG pos after RFG
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets positive setpoint limiting after the ramp-function generator.
p50301[0...n]
RFG negative setpoint limit after ramp-function generator / RFG neg after RFG
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets negative setpoint limiting after the ramp-function generator.
p50302[0...n]

RFG ramp-up integrator operating mode / RFG integ op mode

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the operating mode for the ramp-up integrator.
The ramp-up integrator controls the changing over of the ramp-function generator parameter sets as appropriate for
the set operating mode once the setpoint has been reached for the first time.
Value:
0:
1:
2:
3:
Note:
If p50302 = 0:
- The parameter sets are not changed over and ramp-function generator setting 1 is always used (or the setting made
using p50637, p50638).
If p50302 = 1:
- Once the setpoint has been reached for the first time, the ramp-function generator parameter set is changed over
from 1 to 0.
If p50302 = 2:
- Once the setpoint has been reached for the first time, the ramp-function generator parameter set is changed over
from 1 to 2.
If p50302 = 3:
- Once the setpoint has been reached for the first time, the ramp-function generator parameter set is changed over
from 1 to 3.
p50303[0...n]

RFG ramp-up time 1 / RFG t_ramp-up 1

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the ramp-up time for ramp-function generator parameter set 1.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
RFG normal operation
Operating mode 1
Operating mode 2
Operating mode 3
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650.00 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3155
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 3155
Unit selection: -
Expert list: 1
Factory setting
-100.00 [%]
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
437