2 Parameters
2.2 List of parameters
r52025

CO: CUD analog input 6 result / CUD AI 6 res

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the conversion result at analog input 6 (X177.7/8) on the CUD.
r52026
CO: CUD analog output 0 value after smoothing / CUD AO 0 v aft sm
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for analog output 0 (X177.49/50) on the CUD.
Dependency:
Refer to: p50750
Note:
AO: Analog Output
r52027

CO: CUD analog output 1 value after smoothing / CUD AO 1 v aft sm

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for analog output 1 (X177.51/52) on the CUD.
Dependency:
Refer to: p50755
Note:
AO: Analog Output
r52047
CO: Ramp-function generator braking distance (Unsigned32) / RFG brake dist U32
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the braking distance required as increments of the pulse encoder defined in p0400.
The pulse encoder to be used must be selected using p50331.
The required braking distance is calculated assuming that the speed setpoint at the ramp-function generator input
has been set to 0 and the speed actual value is approaching 0, taking the set ramp-down time and roundings into
consideration.
Note:
For p0400[p50331] = 0, a braking distance of 0 is displayed.
The braking distance calculation is only correct if the ramp-down time and the roundings do not change during
braking (p50302, r00899.5, p50637, p50638).
564
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2090
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2095
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2095
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 3152
Unit selection: -
Expert list: 1
Factory setting
-