2 Parameters
2.2 List of parameters
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
r2032

Master control control word effective / PcCtrl STW eff

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the effective control word 1 (STW1) of the drive for the master control.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
Notice:
The master control only influences control word 1 and speed setpoint 1. Other control words/setpoints can be
transferred from another automation device.
Note:
OC: Operating condition
p2035

Fieldbus interface USS PIV drive object number / Fieldbus USS DO_no

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
1
Description:
Sets the drive object number for communication via the field bus interface (USS).
Dependency:
Refer to: p0978
Note:
p2035 defines the destination for USS parameter requests (PIV).
p0978[0] defines the destination for USS process data (PZD).
The parameter is available globally on all drive objects.
The parameter is not influenced by setting the factory setting.
p2037

IF1 PROFIdrive STW1.10 = 0 mode / IF1 PD STW1.10=0

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the processing mode for PROFIdrive STW1.10 "master control by PLC".
Generally, control world 1 is received with the first receive word (PZD1) (this is in conformance to the PROFIdrive
profile). The behavior of STW1.10 = 0 corresponds to that of the PROFIdrive profile. For other applications that
deviate from this, the behavior can be adapted using this particular parameter.
Value:
0:
1:
2:
Recommendation:
Do not change the setting p2037 = 0.
128
Signal name
ON/OFF1
OC / OFF2
OC / OFF3
Operation enable
Ramp-function generator enable
Start ramp-function generator
Speed setpoint enable
Acknowledge fault
Jog bit 0
Jog bit 1
Master ctrl by PLC
Freeze setpoints and continue to process sign-of-life
Freeze setpoints and sign-of-life
Do not freeze setpoints
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
62
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0