Function Generator Control / Fg Control; Function Generator Status / Fg Status; Bo: Function Generator Status Signal / Fg Status Signal; Function Generator Mode / Fg Operating Mode - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p4800

Function generator control / FG control

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
The function generator is started with p4800 = 1.
The signal is only generated for a 1 signal of binector input p4819.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p4819
r4805

Function generator status / FG status

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Displays the actual status of the function generator.
Value:
0:
1:
2:
3:
4:
5:
6:
Dependency:
Refer to: p4800, p4819
r4806.0

BO: Function generator status signal / FG status signal

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the status of the function generator.
0 signal: Function generator inactive
1 signal: Function generator running
Bit field:
Bit
00
p4810

Function generator mode / FG operating mode

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Sets the operating mode of the function generator.
276
Stop function generator
Start function generator
Check function generator parameterization
Start function generator without enable signals
Inactive
Generate accelerating ramp to offset
Generate parameterized signal shape
Generate braking ramp
Function generator stopped due to missing enable signals
Function generator waits for BI: p4819
Function generator parameterization has been checked
Signal name
Bit 0
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
99
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
0 signal
OFF
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
SINAMICS DCM
FP
-