Suppress Active Fault / Supp Act Flt; Co: Load Speed / N_Load; Co: Load Speed Smoothed / N_Load Smooth; Completion Of Quick Commissioning / Compl Quick_Comm - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p3135

Suppress active fault / Supp act flt

DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Messages
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the suppression of r2139.3 "Fault present" for certain fault responses.
Bit field:
Bit
08
10
Dependency:
Refer to: p0491, r2139
Note:
Depending on the suppression of a fault reaction in this parameter, r2139.1 "Acknowledgement required" is set when
at least one fault occurs.
Re bit 08:
The suppression is only effective if p0491 = 1.
r3770

CO: Load speed / n_load

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Display and connector output for the load speed for APC (Advanced Positioning Control).
Dependency:
Refer to: r3771
r3771[0...1]

CO: Load speed smoothed / n_load smooth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Display and connector output for the speed actual values for APC (Advanced Positioning Control).
Index 0:
Displays the smoothed load speed.
Index 1:
Displays the load/motor speed actual value weighted with p3702 for p3700.8=1.
Index:
[0] = Load actual value speed smoothed
[1] = Load/motor actual speed weighted
Dependency:
Refer to: p1441, r3770
p3900

Completion of quick commissioning / Compl quick_comm

DC_CTRL,
Can be changed: C2(1)
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Exits quick commissioning (p0010 = 1) with automatic calculation of all parameters of all existing drive data sets that
depend on the entries made during quick commissioning.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Suppression of fault response ENCODER
Suppression of fault response NONE
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
OFF
OFF
Access level: 3
Func. diagram: 1580, 4711
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 1580, 4711
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents