2 Parameters
2.2 List of parameters
r0068[0...1]

CO: Absolute current actual value / I_act abs val

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [A]
Description:
Displays actual absolute current.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0027, p0045
Note:
The absolute value of the current actual value is available smoothed (r0027 with 100 ms, r0068[1] with p0045) and
unsmoothed (r0068[0]).
r0080[0...1]

CO: Torque actual value / M_act

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [Nm]
Description:
Display and connector output for actual torque value.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0031, p0045
Note:
The value is available smoothed (r0031 with 100 ms, r0080[1] with p0045) and unsmoothed (r0080[0]).
r0082[0...1]

CO: Active power actual value / P_act

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [kW]
Description:
Displays the instantaneous active power.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0032
Note:
The active power is available smoothed (r0032 with 100 ms, r0082[1] with p0045) and unsmoothed (r0082[0]).
p0097

Select drive object type / Select DO type

CU_DC, CU_DC_R,
Can be changed: C1(1)
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Topology
Not for motor type: -
Min
0
Description:
Executes an automatic device configuration.
In so doing, p0099, p0107 and p0108 are appropriately set.
Value:
0:
15:
Dependency:
Refer to: r0098, p0099
Note:
For p0097 = 0, p0099 is automatically set to the factory setting.
44
No selection
Drive object type DC_CTRL
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: 14_5
Scaling: r2004
Max
- [kW]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
15
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6850
Unit selection: -
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 6850
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [kW]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0