Co/Bo: Control Word Bop / Stw Bop; Speed Setpoint Smoothed / N_Set Smth; Co: Actual Speed Smoothed / N_Act Smooth; Speed Actual Value Rpm Smoothed / N_Act Rpm Smooth - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r0019.0...14

CO/BO: Control word BOP / STW BOP

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the control word for the Basic Operator Panel (BOP).
Bit field:
Bit
00
01
02
07
13
14
r0020

Speed setpoint smoothed / n_set smth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Displays the actual smoothed speed setpoint at the speed controller input.
Dependency:
Refer to: r0060
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0021

CO: Actual speed smoothed / n_act smooth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Displays the smoothed actual value of the motor speed.
Dependency:
Refer to: r0022, p0045, r0063
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021, r0022, r0063[1] with p0045) and unsmoothed (r0063[0]).
r0022

Speed actual value rpm smoothed / n_act rpm smooth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Displays the smoothed actual value of the motor speed.
r0022 is identical to r0021, however, it always has units of rpm and contrary to r0021 cannot be changed over.
Dependency:
Refer to: r0021, p0045, r0063
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
ON / OFF (OFF1)
No coast-down / coast-down (OFF2)
No Quick Stop / Quick Stop (OFF3)
Acknowledge fault (0 -> 1)
Motorized potentiometer raise
Motorized potentiometer lower
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
No coast down
No Quick Stop
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2000
Max
- [rpm]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 9912
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF (OFF1)
Coast down (OFF2)
Quick Stop (OFF3)
No
No
No
Access level: 2
Func. diagram: 3155
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: 6810
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [rpm]
FP
-
-
-
-
-
-
39