2 Parameters
2.2 List of parameters
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Free function blocks
DC_CTRL_S
Not for motor type: -
Min
- [%]
Description:
Display and connector output for frequently used percentage values.
Index:
[0] = Fixed value +0 %
[1] = Fixed value +5 %
[2] = Fixed value +10 %
[3] = Fixed value +20 %
[4] = Fixed value +50 %
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
Dependency:
Refer to: p2900, p2901, p2930
Note:
The signal sources can, for example, be used to interconnect scalings.
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Free function blocks
DC_CTRL_S
Not for motor type: REL
Min
-100000.00 [Nm]
Description:
Setting and connector output for a fixed torque value.
Dependency:
Refer to: p2900, p2901, r2902
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can, for example, be used to interconnect a supplementary torque.
p3100

RTC time stamp mode / RTC t_stamp mode

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3100 = 2: Time stamp, operating hours + 01.01.2000
Notice:
The realtime format (p3100 = 1), once selected, remains until the next time that the system is switched off. Switching
back to operating hours (p3100 = 0) or operating hours + 01.01.2000 (p3100=2) is prevented.
Note:
RTC: Real-time clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
198
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 7_1
Scaling: p2003
Max
100000.00 [Nm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
SINAMICS DCM