2 Parameters
2.2 List of parameters
r2019[0...7]
Comm IF error statistics / Comm err
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the receive errors at the commissioning interface (RS232).
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
p2020
Field bus interface baud rate / Field bus baud
CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
4
Description:
Sets the baud rate for the fieldbus interface USS.
Value:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
Note:
Fieldbus IF: Fieldbus interface
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
The parameter is set to the factory setting when the protocol is reselected.
p2021
Field bus interface address / Field bus address
CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the address for the fieldbus interface USS.
Dependency:
Refer to: p2030
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
The parameter is set to the factory setting when the protocol is reselected.
126
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
57600 baud
76800 baud
93750 baud
115200 baud
187500 baud
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
13
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
31
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
8
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM