2 Parameters
2.2 List of parameters
r4709[0...1]
Trace memory space required for measuring functions / Trace mem required
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the required memory in bytes for the actual parameterization.
This applies, if the trace for the measurement functions is used.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
p4710[0...1]

Trace trigger condition / Trace Trig_cond

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
1
Description:
Sets the trigger condition for the trace.
Value:
1:
2:
3:
4:
5:
6:
7:
8:
Index:
[0] = Trace 0
[1] = Trace 1
p4711[0...5]

Trace trigger signal / Trace trig_signal

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Selects the trigger signal for the trace.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
Dependency:
Only effective when p4710 does not equal 1.
Note:
It only makes sense to trace the PINs using the commissioning software.
For index 2(4) and 3(5) equal to zero, index 0(1) can only be written and vice versa.
Re index 0 ... 1:
Here, the trigger signal for trace 0 or 1 is entered as parameter in the BICO format.
For trace with a physical address (p4789), the data type of the trigger signal is set here.
258
Immediate trace start
Positive edge
Negative edge
Entry to hysteresis band
Leaving hysteresis band
Trigger at bit mask
Start with function generator
Trigger at bit mask with edge
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0