p50132[0...n]
Field current for motor flux 60 % / I_field flux 60%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 60 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50131 and less than p50133 can be set.
p50133[0...n]
Field current for motor flux 65 % / I_field flux 65%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 65 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50132 and less than p50134 can be set.
p50134[0...n]
Field current for motor flux 70 % / I_field flux 70%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 70 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50133 and less than p50135 can be set.
p50135[0...n]
Field current for motor flux 75 % / I_field flux 75%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 75 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50134 and less than p50136 can be set.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
44.6 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
48.9 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
53.6 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
58.9 [%]
407