Adapt Arm Curr Controller Intermittent Adapt Activation; Adaptation Armature Current Controller Limiting / Adapt Ia_Ctrl Lim; Adapt Arm Curr Controller Intermittent Adapt Kp Increase; Adaptation Field Current Controller Changeover Input - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50572[0...n]
Adapt arm curr controller intermittent adapt activation / Adapt Interm Act
DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate the intermittent adaptation for the armature current controller.
Value:
0:
1:
Dependency:
Refer to: p50570, p50571, r52350
p50573[0...n]

Adaptation armature current controller limiting / Adapt Ia_ctrl lim

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1.0 [%]
Description:
Setting to limit the armature current controller adaptation.
Dependency:
Refer to: p50571, p50572, r52350
p50574[0...n]
Adapt arm curr controller intermittent adapt Kp increase / Ad Interm Kp incr
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0
Description:
Sets the Kp increase for the intermittent adaptation for the armature current controller.
Dependency:
Refer to: p50572
p50575[0...n]
Adaptation field current controller changeover input / Adapt If chgov inp
DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the input variable for the field current controller adaptation.
Value:
0:
1:
Dependency:
Refer to: p50576, p50577
p50576[0...n]
Adaptation field current controller non-linear L activation / Adapt n_lin act
DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate the adaptation of non-linear inductances for the field current controller.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Intermittent adaptation effective
Fixed value 100 %
If_act r52265
If_set r52268
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
1000.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10.0
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6853
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6853
Unit selection: -
Expert list: 1
Factory setting
200.0 [%]
Access level: 2
Func. diagram: 6853
Unit selection: -
Expert list: 1
Factory setting
1.0
Access level: 2
Func. diagram: 6908
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6908
Unit selection: -
Expert list: 1
Factory setting
0