Co: Cl-Loop Field Curr Ctrl Prectr And Field Curr Controller Output; Co: Closed-Loop Field Current Control Current Controller Output; Co: Cl-Loop Field Curr Control Curr Controller Proportional Comp; Co: Cl-Loop Field Curr Control Curr Controller Integral Comp - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52252
CO: Cl-loop field curr ctrl prectr and field curr controller output / If_ctr prec+ctrl
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the output value from pre-control and the field current controller.
r52260
CO: Closed-loop field current control current controller output / If_ctr I_ctr outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the output in the case of closed-loop field current control.
r52261
CO: Cl-loop field curr control curr controller proportional comp / If_ctr I_ctr P com
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the proportional component in the case of closed-loop field current control.
r52262
CO: Cl-loop field curr control curr controller integral comp / If_ctr I_ctr I com
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the integral component in the case of closed-loop field current control.
r52263
CO: Cl-loop field curr ctrl current controller set/act val diff / If_ctr I_ctr dif
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the setpoint/actual value difference in the case of closed-loop field current control.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
587