2 Parameters
2.2 List of parameters
p50745

Analog input main actual value smoothing time constant / AI m act T

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the time constant for smoothing the signal from the "main actual value" analog input (XT1.103/104).
p50746
BI: Signal source to enable analog input main actual value / AI m act ena sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling the analog input for the "main actual value (XT1.103/104).
Note:
1 signal: Analog input enabled
0 signal: Analog input not enabled (r52013 = 0%).
p50747
Analog input main actual value setpoint simulation / AI m_actV sim setp
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-130.0 [%]
Description:
Sets the setpoint for the simulation of the "main actual value" analog input (XT1.103/104).
Dependency:
Refer to: p50749
Note:
Simulation is selected using p50749 = 1.
p50749
Analog input main actual value simulation selection / AI m_actV sim sel
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to select the simulation of the "main actual value" analog input (XT1.103/104).
Value:
0:
1:
Dependency:
Refer to: p50747
Note:
The setpoint for the simulation is set in p50747.
p50750

CI: CUD analog output 0 signal source / CUD AO 0 sig s

DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the output value at analog output 0 (X177.49/50).
510
Simulation deactivated
Simulation activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
130.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2095
Unit selection: -
Expert list: 1
Factory setting
0