If1 Profidrive Stw/Zsw Interface Mode / Pd Stw/Zsw If Mode; Select Debug Monitor Interface / Debug Monit Select; Fieldbus Interface Monitoring Time / Fieldbus T_Monit; Profibus Ident Number / Pb Ident No. - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Note:
If the STW1 is not transferred according to the PROFIdrive with PZD1 (with bit 10 "master control by PLC"), then
p2037 should be set to 2.
p2038

IF1 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the interface mode of the PROFIdrive control words and status words.
When selecting a telegram via p0922 (p2079), this parameter influences the device-specific assignment of the bits in
the control and status words.
Value:
0:
2:
Dependency:
Refer to: p0922, p2079
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2039

Select debug monitor interface / Debug monit select

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the serial interface for the debug monitor.
With p2039 = 1, the serial interface COM2 (X179) is set.
Other values are not permitted.
p2040

Fieldbus interface monitoring time / Fieldbus t_monit

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0 [ms]
Description:
Sets the monitoring time to monitor the process data received via the fieldbus interface.
If no process data is received within this time, then an appropriate message is output.
Note:
p2040 = 0:
Monitoring is de-activated.
p2042

PROFIBUS Ident Number / PB Ident No.

CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the PROFIBUS Ident Number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with Ident Number 3AA0 hex).
Value:
0:
1:
Note:
Every change only becomes effective after a POWER ON.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
SINAMICS
VIK-NAMUR
SINAMICS
VIK-NAMUR
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1999999 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
100 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
129

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents