2 Parameters
2.2 List of parameters
p50120[0...n]
Field current for motor flux 0 % / I_field flux 0%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 0 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values less than p50121 can be set.
p50121[0...n]
Field current for motor flux 5 % / I_field flux 5%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 5 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50120 and less than p50122 can be set.
p50122[0...n]
Field current for motor flux 10 % / I_field flux 10%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 10 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50121 and less than p50123 can be set.
p50123[0...n]
Field current for motor flux 15 % / I_field flux 15%
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 15 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50122 and less than p50124 can be set.
404
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
3.7 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
7.3 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
11.0 [%]