Co: Tm150 Group Temperature Average Actual Value / Tm150 Grp Temp Av; Tm150 Group Sensor Error Effect / Tm150 Error Effect; Tm150 Fault Threshold/Alarm Threshold Hysteresis / Tm150 Thresh Hyst - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r4114[0...2]

CO: TM150 group temperature average actual value / TM150 grp temp av

TM150
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [°C]
Description:
Display and connector output for the average value of each group for the Terminal Module 150 (TM150).
This value is calculated from the actual temperature values (r4105[0...11]) of each group.
Recommendation:
The following connector inputs can use these connector outputs for interconnection:
- CI: p0603
- CI: p0608[0...3]
- CI: p0609[0...3]
- CI: p2051
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Dependency:
Refer to: r4105, p4111, r4112, r4113
Note:
If one group is assigned sensor type "PTC" or "bimetal NC contact", then the average value -300 °C is output.
p4117[0...2]

TM150 group sensor error effect / TM150 error effect

TM150
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the effect for an error of a sensor of a group for Terminal Module TM150 (TM150).
For p4117 = 0, the following applies:
The defective temperature sensor assigned to a group is not take into account when forming the group.
For p4117 = 1, the following applies:
For a sensor error, for the maximum value, minimum value and average value of the corresponding group, a value of
-300 °C is output.
Value:
0:
1:
Index:
[0] = Group 0
[1] = Group 1
[2] = Group 2
Dependency:
Refer to: r4105, p4111, r4112, r4113, r4114
p4118[0...11]

TM150 fault threshold/alarm threshold hysteresis / TM150 thresh hyst

TM150
Can be changed: T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0 [K]
Description:
Sets the hysteresis for the fault threshold/alarm threshold (p4102[0...23]) for the Terminal Module 150 (TM150).
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
[5] = Temperature channel 5
248
Skip sensor
Output value = -300 °C
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
50 [K]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 9625
Unit selection: -
Expert list: 1
Factory setting
- [°C]
Access level: 1
Func. diagram: 9625
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 9626, 9627
Unit selection: -
Expert list: 1
Factory setting
5 [K]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading