Speed Controller Adaptation Droop X Coordinate 1 / Adapt Droop X1; Speed Controller Adaptation Kp X Coordinate 2 / Adapt Kp X2; Speed Controller Adaptation Tn X Coordinate 2 / Adapt Tn X2 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50558[0...3]

Speed controller adaptation droop x coordinate 1 / Adapt droop x1

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the x coordinate for pair of values 1 for adaptation of the droop.
Notice:
The following condition applies for x coordinate 1/2:
p50558 < p50561
Note:
The adaptation of the droop is defined using 2 pairs of values.
Pair of values 1:
p50558/p50552 (x/y coordinate)
Pair of values 2:
p50561/p50227 (x/y coordinate)
p50559[0...n]

Speed controller adaptation Kp x coordinate 2 / Adapt Kp x2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the x coordinate for pair of values 2 for adaptation of the P gain (Kp).
Notice:
The following condition applies for x coordinate 1/2:
p50556 < p50559
Note:
The adaptation of the P gain (Kp) is defined using 2 pairs of values.
Pair of values 1:
p50556/p50550 (x/y coordinate)
Pair of values 2:
p50559/p50225 (x/y coordinate)
p50560[0...n]

Speed controller adaptation Tn x coordinate 2 / Adapt Tn x2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the x coordinate for pair of values 2 for adaptation of the integral time (Tn).
Notice:
The following condition applies for x coordinate 1/2:
p50557 < p50560
Note:
The adaptation of the integral time (Tn) is defined using 2 pairs of values.
Pair of values 1:
p50557/p50551 (x/y coordinate)
Pair of values 2:
p50560/p50226 (x/y coordinate)
476
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents