p51596[0...n]

Interphase resistance in 12-pulse operation / R_intph 12-pulse

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [ohm]
Description:
Sets the resistance of an interphase transformer in 12-pulse operation.
Note:
The parameter is set automatically during the "optimization run for pre-control and the current controller for the
armature converter" (p50051 = 25).
p51597[0...n]

Field inductance reduction factor / L_field red fact

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
10 [%]
Description:
Sets the reduction factor for the current-dependent field inductance.
At 100% motor rated current (p50102), the field inductance is lower than it is at field current 0 by this factor.
Dependency:
Refer to: p50116
Note:
The parameter is set automatically during the "optimization run for pre-control and the current controller for the field
current controller" (p50051 = 24).
r51598

Short-circuit voltage Uk, per unit / V_sh-cct Uk p.u.

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the per unit short-circuit voltage of the line supply.
The value is calculated from the commutation inductance (p51592) and the rated converter data (In = r50072[1], Vn =
p50078[0], fn = r50017).
p51607[0...n]

BI: Setpoint processing reduction signal source / Red sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for activating/de-activating the reduction factor for the speed setpoint.
Dependency:
Refer to: p51608, r52194, r52195
Note:
Dependent upon binector input (p51607):
1 signal:
The reduction factor (p51608) is de-activated (r52194 = r52195).
0 signal:
The reduction factor (p51608) is activated (r52194 = r52195 x p51608).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000.000 [ohm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000 [ohm]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
100 [%]
Access level: 1
Func. diagram: 6854
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
1
535