p50962[0...4]

Device fan reset operating hours / Dev_fan reset h

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to reset the operating hours of the device fan that have accumulated.
Value:
0:
1:
Index:
[0] = Fan terminal XV1
[1] = Fan terminal XV2
[2] = Fan terminal XV3
[3] = Fan terminal XV4
[4] = Fan ON
Dependency:
Refer to: r50960, p50961
Note:
Procedure to reset the operating hours:
Set p50962[x] = 1
The parameter is automatically set to zero after this is done.
p50963

Behavior of the fan control / Behavior fan ctrl

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Behavior of the fan control:
0 : The fan control takes into account the temperature sensor.
1 : The fan control does not take into account the temperature sensor.
Value:
0:
1:
Dependency:
Refer to: r50960, p50961
Note:
Setting 1:
The fan is only switched off after the parameterized fan run-on time, independent of the various temperature
measurements and independent of the calculated thyristor temperature rise (=barrier layer temperature of the
thyristors).
As a consequence, it is also possible to acknowledge a fan fault even at ambient temperatures > 35°.
p51117[0...15]

BI: Binector-connector converter signal source / Bin/con sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for the binector inputs on the binector-connector converter.
Dependency:
Refer to: r52620
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Inactive
Reset
The fan control takes into account the temperature sensor.
The fan control doesn't take into account the temperature sensor
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8045
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8047
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9300
Unit selection: -
Expert list: 1
Factory setting
0
529