p2002

Reference current / I_ref

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
0.10 [Arms]
Description:
Sets the reference quantity for current.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
p2003

Reference torque / M_ref

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
0.01 [Nm]
Description:
Sets the reference quantity for torque.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
r2004

Reference power / P_ref

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
DC_CTRL_S
P-Group: Communications
Not for motor type: -
Min
- [kW]
Description:
Displays the reference quantity for power.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
Dependency:
This value is calculated as follows:
Closed-loop control: Calculated from torque times speed.
Refer to: p2000, p2001, p2002, p2003
Note:
If a BICO interconnection is established between different physical quantities, then the particular reference quantities
are used as internal conversion factor.
The reference power is calculated as follows:
- 2 * Pi * reference speed / 60 * reference torque (motor)
p2005

Reference angle / Reference angle

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
90.00 [°]
Description:
Sets the reference quantity for angle.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
124
Calculated: CALC_MOD_ALL
Dyn. index: -
Unit group: -
Scaling: -
Max
100000.00 [Arms]
Calculated: CALC_MOD_ALL
Dyn. index: -
Unit group: 7_2
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: -
Unit group: 14_10
Scaling: -
Max
- [kW]
Calculated: CALC_MOD_ALL
Dyn. index: -
Unit group: -
Scaling: -
Max
180.00 [°]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [Arms]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
1.00 [Nm]
Access level: 3
Func. diagram: 9566, 9568,
9572
Unit selection: p0505
Expert list: 1
Factory setting
- [kW]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
90.00 [°]