Power Unit Code Number Actual / Pu Code No. Act; Power Unit Code Number / Pu Code No; Firmware Package Name / Fw Pkg Name; Automatic Calculation Motor/Control Parameters / Calc Auto Par - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0200[0...n]

Power unit code number actual / PU code no. act

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Converter
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the unique code number of the power unit.
Note:
r0200 = 0: No power unit found
p0201[0...n]

Power unit code number / PU code no

DC_CTRL,
Can be changed: C2
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Code number of the power unit.
Each time the system boots, the code number is transferred from the data of the power unit to r0200 and to p0201.
r0203[0...15]

Firmware package name / FW pkg name

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned8
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the name of the firmware package on the memory card/device memory.
r0203[0]: Name character 1
...
r0203[15]: Name character 16
For the commissioning software, the ASCII characters are displayed uncoded.
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
p0340[0...n]

Automatic calculation motor/control parameters / Calc auto par

DC_CTRL,
Can be changed: C2(3), T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Motor
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Setting to automatically calculate motor parameters and closed-loop control parameters from rating plate data.
Value:
0:
1:
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
62
No calculation
Complete calculation
Calculated: -
Dyn. index: PDS
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: PDS
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents