2 Parameters
2.2 List of parameters
p50180[0...n]

Torque limiting torque limit 1 positive / T lim 1 pos

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets positive torque limit 1.
Dependency:
Refer to: p50182
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
p50181[0...n]

Torque limiting torque limit 1 negative / T lim 1 neg

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets negative torque limit 1.
Dependency:
Refer to: p50183
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
p50182[0...n]

Torque limiting torque limit 2 positive / T lim 2 pos

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets positive torque limit 2.
Dependency:
Refer to: p50180
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
p50183[0...n]

Torque limiting torque limit 2 negative / T lim 2 neg

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets negative torque limit 2.
Dependency:
Refer to: p50181
Note:
If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
418
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
300.00 [%]
Access level: 1
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
-300.00 [%]
Access level: 2
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
300.00 [%]
Access level: 2
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
-300.00 [%]